{"id":14860,"date":"2024-12-13T09:19:54","date_gmt":"2024-12-13T09:19:54","guid":{"rendered":"https:\/\/www.epicmicron.com\/?p=14860"},"modified":"2024-12-17T07:11:10","modified_gmt":"2024-12-17T07:11:10","slug":"analysis-of-the-heavy-calcium-powder-and-changes-in-d100","status":"publish","type":"post","link":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/","title":{"rendered":"Analyse des schweren Calciumpulvers und \u00c4nderungen in D100"},"content":{"rendered":"<p>Forscher testen die Partikelgr\u00f6\u00dfe mit einem Laser-Partikelgr\u00f6\u00dfenanalysator nach einer einzigen Klassifizierung von schwerem Kalziumpulver. \u00dcberraschenderweise \u00e4nderte sich die Feinpartikelgr\u00f6\u00dfe und der D100-Wert stieg. Nach einer zweiten Klassifizierung stieg der D100-Wert erneut an, was zu weiterer Verwirrung f\u00fchrte.<\/p>\n\n\n\n<p>Zun\u00e4chst bestand der Verdacht, dass sich m\u00f6glicherweise andere Pulver mit dem Kalziumpulver vermischt haben k\u00f6nnten. Nachdem diese M\u00f6glichkeit jedoch ausgeschlossen wurde, blieb das Problem weiterhin bestehen. Konzentrieren wir uns also auf den Klassifizierungsprozess und die Erkennungsmethoden, um zu verstehen, warum dies geschieht.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"900\" height=\"392\" src=\"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes.webp\" alt=\"Calciumcarbonatpulver in verschiedenen Partikelgr\u00f6\u00dfen\" class=\"wp-image-14861\" srcset=\"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes.webp 900w, https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes-300x131.webp 300w, https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes-768x335.webp 768w, https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes-18x8.webp 18w, https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes-600x261.webp 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><figcaption class=\"wp-element-caption\">Calciumcarbonatpulver in verschiedenen Partikelgr\u00f6\u00dfen<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Ausschlie\u00dflich <a href=\"https:\/\/en.wikipedia.org\/wiki\/Contamination\">Kontamination<\/a>: Fokus auf Klassifizierung und Erkennung<\/h2>\n\n\n\n<p>Es ist unwahrscheinlich, dass es sich mit anderen Pulvern vermischt, also schauen wir uns den Klassifizierungsprozess und die Nachweismethoden an. Hier ist eine einfache Analyse, um Klarheit zu schaffen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Mahleinrichtung und Sichterfunktion<\/h2>\n\n\n\n<p>Der <a href=\"https:\/\/www.epicmicron.com\/de\">Schleifger\u00e4te<\/a> bl\u00e4st Pulverpartikel durch einen aufw\u00e4rts gerichteten Luftstrom in den Klassierer. Dieser Klassierer oder Luftstromklassierer nutzt mechanische Zentrifugalkraft, um die Pulverpartikel im Luftstrom zu beschleunigen. Gr\u00f6\u00dfere Partikel werden nach au\u00dfen geschleudert, treffen auf die Eisenwand und verlieren kinetische Energie, wodurch sie wieder nach unten fallen. Kleinere Partikel verbleiben in der Mitte des Luftstroms und werden zum Staubsammler oder anderen nachfolgenden Verarbeitungsstufen bef\u00f6rdert.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Laser-Partikelgr\u00f6\u00dfenanalysator<\/h3>\n\n\n\n<p>Der Laser-Partikelgr\u00f6\u00dfenanalysator testet Partikelgr\u00f6\u00dfen, indem er verd\u00fcnnte Pulverpartikel in eine w\u00e4ssrige L\u00f6sung gibt. Der Analysator verwendet einzelne oder doppelte Lichtquellen mit bestimmten Wellenl\u00e4ngen, um Interferenzen oder Beugungen zu induzieren. Er basiert auf Modellen wie dem <strong>MIE<\/strong> oder <strong>Fraunhofer<\/strong> um die Wechselwirkung von Licht mit Partikeln zu simulieren. Anschlie\u00dfend berechnet es statistische Daten zum Volumendurchmesser.<\/p>\n\n\n\n<p><strong>MIE-Modell<\/strong>: Wird haupts\u00e4chlich f\u00fcr Partikelgr\u00f6\u00dfen im Nanometerbereich verwendet.<\/p>\n\n\n\n<p><strong>Fraunhofer-Modell (F-Modell)<\/strong>: Besser f\u00fcr gr\u00f6\u00dfere Partikelgr\u00f6\u00dfen geeignet.<\/p>\n\n\n\n<p>Das Prinzip hinter diesen Modellen ist komplex, aber jedes Modell ist f\u00fcr unsere Analyse auf unterschiedliche Partikelgr\u00f6\u00dfenbereiche zugeschnitten.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Warum steigt D100 st\u00e4ndig an?<\/h2>\n\n\n\n<p>Wenn ein Pulver mehreren Klassifizierungen unterzogen wird, kann dies dazu f\u00fchren, dass der D100-Wert (die Partikelgr\u00f6\u00dfe, bei der 100% des Materials kleiner ist) mit jeder Klassifizierung steigt. Dies hat h\u00e4ufig folgende Gr\u00fcnde:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Partikelumverteilung<\/strong>: Nach jeder Klassierung k\u00f6nnen feinere Partikel entfernt werden, so dass ein gr\u00f6\u00dferer Anteil gr\u00f6berer Partikel \u00fcbrig bleibt. Das Ergebnis ist eine allgemeine Verschiebung der Partikelgr\u00f6\u00dfenverteilung, was zu einer Erh\u00f6hung des D100-Wertes f\u00fchrt.<\/li>\n\n\n\n<li><strong>Klassifiziereffizienz<\/strong>: Die Effizienz des Klassifizierers kann variieren, insbesondere bei der Verarbeitung von Pulvern mit einer breiten Partikelgr\u00f6\u00dfenverteilung. Eine inkonsistente Klassifizierung kann dazu f\u00fchren, dass feinere Partikel wieder in das System gelangen, was zu \u00c4nderungen der Partikelgr\u00f6\u00dfenergebnisse f\u00fchrt.<\/li>\n\n\n\n<li><strong>Variabilit\u00e4t der Messmethoden<\/strong>: Die Methoden des Laser-Partikelgr\u00f6\u00dfenanalysators, insbesondere die MIE- und Fraunhofer-Modelle, k\u00f6nnen je nach Art der Partikel und der zur Erkennung verwendeten Wellenl\u00e4nge zu Messabweichungen f\u00fchren.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Die Rolle von D97, D98 und D100 in der Laserpartikelgr\u00f6\u00dfenanalyse<\/h3>\n\n\n\n<p>Im Bereich der Partikelgr\u00f6\u00dfenanalyse liegt der Fokus vor allem auf <strong>T97-Serie<\/strong>\u00a0oder <strong>T98-Serie<\/strong>\u00a0Werte, die die h\u00f6chsten Partikelgr\u00f6\u00dfen darstellen. W\u00e4hrend Forscher selten diskutieren <strong>D100<\/strong>. Wenn Sie jedoch die Testergebnisse von Laser-Partikelgr\u00f6\u00dfenanalysatoren \u2013 ob von Malvern, Bexter oder anderen Ger\u00e4ten \u2013 genau untersuchen, werden Sie feststellen, dass die <strong>T97-Serie<\/strong>\u00a0Und <strong>D100<\/strong>\u00a0Werte k\u00f6nnen erheblich abweichen. Dieser Unterschied, der oft im Bereich von 0,02% bis 0,04% liegt, unterstreicht die Komplexit\u00e4t der Partikelgr\u00f6\u00dfenmessung.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Den Wert verstehen<\/h3>\n\n\n\n<p>Der <strong>D100<\/strong>&nbsp;Der Wert stellt die Partikelgr\u00f6\u00dfe dar, bei der 100% der Probe kleiner ist. Obwohl dieser Wert entscheidend erscheinen mag, wird er oft \u00fcberschattet von der <strong>T97-Serie<\/strong>&nbsp;Und <strong>T98-Serie<\/strong>&nbsp;Messungen, die sich auf den oberen Grenzwert konzentrieren. Die Diskrepanz zwischen D97- und D100-Werten ist nicht unbedingt auf Fehler im Messprozess zur\u00fcckzuf\u00fchren, sondern vielmehr auf die <strong>indirekte Natur<\/strong>&nbsp;der Laser-Partikelgr\u00f6\u00dfenanalyse.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Laser-Partikelgr\u00f6\u00dfenanalysator: Indirekte Detektionsmethode<\/h3>\n\n\n\n<p>Laser-Partikelgr\u00f6\u00dfenanalysatoren wie die von Malvern oder Bexter verwenden <strong>Interferenz<\/strong>&nbsp;oder <strong>Beugung<\/strong>&nbsp;Modelle zur Sch\u00e4tzung der Gr\u00f6\u00dfe von Pulverpartikeln. Diese Analysatoren verwenden spezifische mathematische Modelle, wie zum Beispiel die <strong>MIE<\/strong>&nbsp;oder <strong>Fraunhofer<\/strong>&nbsp;Modell zur Berechnung des Volumendurchmessers auf Basis der Interferenzwellen, die bei der Wechselwirkung von Licht mit Pulverpartikeln entstehen.<\/p>\n\n\n\n<p>Dieser Prozess ist jedoch <strong>indirekt<\/strong>\u2014 Die Modelle basieren auf statistischen Berechnungen und nicht auf direkten Messungen. Daher k\u00f6nnen Ungenauigkeiten auftreten, insbesondere bei <strong>Extreme<\/strong>\u00a0des Partikelgr\u00f6\u00dfenbereichs, wie beispielsweise die kleinste (0%) und gr\u00f6\u00dfte (100%) Partikelgr\u00f6\u00dfe. Diese statistische Natur bedeutet, dass die Analyse m\u00f6glicherweise bestimmte gro\u00dfe Partikel statistisch ausschlie\u00dft, die im Verh\u00e4ltnis zur Lichtwellenl\u00e4nge zu selten oder zu gro\u00df sein k\u00f6nnten.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Statistische Ungenauigkeiten bei gro\u00dfen und kleinen Partikeln<\/h3>\n\n\n\n<p>Die Genauigkeit von Laser-Partikelgr\u00f6\u00dfenanalysatoren wird oft begrenzt durch die <strong>statistische Schwellenwerte<\/strong>&nbsp;von den Modellen vorgegeben. Wenn es eine <strong>kleine Zahl<\/strong>&nbsp;Bei sehr feinen Partikeln k\u00f6nnen diese aufgrund statistischer Einschr\u00e4nkungen bei der Probenentnahme \u00fcbersehen werden. Umgekehrt gelangen mit zunehmender Anzahl gr\u00f6berer Partikel in den Probenpool und tragen zur beobachteten Partikelgr\u00f6\u00dfenverteilung bei. Dies f\u00fchrt zu <strong>D100<\/strong>&nbsp;Die Werte werden von diesen statistischen Schwellenwerten beeinflusst, die wiederum untrennbar mit der Reproduzierbarkeit und den Nachweisgrenzen des Analysators verbunden sind.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Abschluss<\/h2>\n\n\n\n<p>Laser-Partikelgr\u00f6\u00dfenanalysatoren liefern wertvolle statistische Daten durch ein indirektes Messverfahren. Sie bieten Reproduzierbarkeit innerhalb bestimmter Partikelgr\u00f6\u00dfenbereiche und sind \u00e4u\u00dferst n\u00fctzlich f\u00fcr die Steuerung von Produktions- und Anwendungsprozessen. Pulver besteht aus einem breiten Spektrum an Partikelgr\u00f6\u00dfen, und die Analyse dieser Partikel erfordert ein Verst\u00e4ndnis sowohl der feinen als auch der groben Extreme. Direkte Messverfahren wie die Elektronenmikroskopie bieten einen genaueren, visuellen Ansatz zur Partikelgr\u00f6\u00dfenbeobachtung, sind jedoch h\u00e4ufig ressourcenintensiver.<\/p>\n\n\n\n<p>Um die Gr\u00fcnde f\u00fcr die mehrfache Klassifizierung von schwerem Kalziumpulver und die \u00c4nderungen des D100-Werts zu verstehen, m\u00fcssen sowohl der Klassifizierungsprozess als auch die Einschr\u00e4nkungen der Nachweismethoden ber\u00fccksichtigt werden. Die mehrfachen Klassifizierungszyklen und das Verhalten des Klassifikators sowie die vom Laser-Partikelgr\u00f6\u00dfenanalysator verwendeten Modelle spielen alle eine Rolle bei den beobachteten \u00c4nderungen der Partikelgr\u00f6\u00dfenverteilung. Durch die Optimierung des Klassifizierungsprozesses und die Gew\u00e4hrleistung konsistenter Nachweismethoden kann das Problem steigender D100-Werte verringert werden.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe title=\"Kugelm\u00fchle und Klassifizierungssystem f\u00fcr Calciumcarbonat-EPIC\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/SVjfmdFpEOc?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Forscher testen die Partikelgr\u00f6\u00dfe mit einem Laser-Partikelgr\u00f6\u00dfenanalysator nach einer einzigen Klassifizierung von schwerem Kalziumpulver. \u00dcberraschenderweise hat sich die feine Partikelgr\u00f6\u00dfe ver\u00e4ndert, und der D100 [\u2026]<\/p>","protected":false},"author":2,"featured_media":14861,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[42],"tags":[],"class_list":["post-14860","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.3 (Yoast SEO v27.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Analysis of the Heavy Calcium Powder and Changes in D100 - Jet Mill Equipment Manufacturer<\/title>\n<meta name=\"description\" content=\"The fine particle size was found to change, and the D100 value increased. After a second classification, the D100 value increased again.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Analysis of the Heavy Calcium Powder and Changes in D100\" \/>\n<meta property=\"og:description\" content=\"The fine particle size was found to change, and the D100 value increased. After a second classification, the D100 value increased again.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/\" \/>\n<meta property=\"og:site_name\" content=\"Jet Mill Equipment Manufacturer\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-13T09:19:54+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-17T07:11:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"900\" \/>\n\t<meta property=\"og:image:height\" content=\"392\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"EPIC Powder\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"EPIC Powder\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/\"},\"author\":{\"name\":\"EPIC Powder\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#\\\/schema\\\/person\\\/786ce0f3af110c7e79ad2d6a8fccaf39\"},\"headline\":\"Analysis of the Heavy Calcium Powder and Changes in D100\",\"datePublished\":\"2024-12-13T09:19:54+00:00\",\"dateModified\":\"2024-12-17T07:11:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/\"},\"wordCount\":1013,\"publisher\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.epicmicron.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/Calcium-carbonate-powder-of-different-particle-sizes.webp\",\"articleSection\":[\"Industry News\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/\",\"url\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/\",\"name\":\"Analysis of the Heavy Calcium Powder and Changes in D100 - Jet Mill Equipment Manufacturer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.epicmicron.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/Calcium-carbonate-powder-of-different-particle-sizes.webp\",\"datePublished\":\"2024-12-13T09:19:54+00:00\",\"dateModified\":\"2024-12-17T07:11:10+00:00\",\"description\":\"The fine particle size was found to change, and the D100 value increased. After a second classification, the D100 value increased again.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.epicmicron.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/Calcium-carbonate-powder-of-different-particle-sizes.webp\",\"contentUrl\":\"https:\\\/\\\/www.epicmicron.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/Calcium-carbonate-powder-of-different-particle-sizes.webp\",\"width\":900,\"height\":392,\"caption\":\"Calcium carbonate powder of different particle sizes\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.epicmicron.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Analysis of the Heavy Calcium Powder and Changes in D100\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#website\",\"url\":\"https:\\\/\\\/www.epicmicron.com\\\/\",\"name\":\"Jet Mill Equipment Manufacturer\",\"description\":\"Dry ultrafine grinding equipment\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.epicmicron.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#organization\",\"name\":\"Jet Mill Equipment Manufacturer\",\"url\":\"https:\\\/\\\/www.epicmicron.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.epicmicron.com\\\/wp-content\\\/uploads\\\/2021\\\/04\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/www.epicmicron.com\\\/wp-content\\\/uploads\\\/2021\\\/04\\\/logo.png\",\"width\":350,\"height\":100,\"caption\":\"Jet Mill Equipment Manufacturer\"},\"image\":{\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.epicmicron.com\\\/#\\\/schema\\\/person\\\/786ce0f3af110c7e79ad2d6a8fccaf39\",\"name\":\"EPIC Powder\",\"url\":\"https:\\\/\\\/www.epicmicron.com\\\/de\\\/author\\\/epic-powder\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Analyse des schweren Calciumpulvers und \u00c4nderungen in D100 - Hersteller von Strahlm\u00fchlenausr\u00fcstung","description":"Es zeigte sich, dass sich die Feinpartikelgr\u00f6\u00dfe ver\u00e4nderte und der D100-Wert anstieg. Nach einer zweiten Klassifizierung stieg der D100-Wert erneut an.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/","og_locale":"de_DE","og_type":"article","og_title":"Analysis of the Heavy Calcium Powder and Changes in D100","og_description":"The fine particle size was found to change, and the D100 value increased. After a second classification, the D100 value increased again.","og_url":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/","og_site_name":"Jet Mill Equipment Manufacturer","article_published_time":"2024-12-13T09:19:54+00:00","article_modified_time":"2024-12-17T07:11:10+00:00","og_image":[{"width":900,"height":392,"url":"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes.webp","type":"image\/webp"}],"author":"EPIC Powder","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"EPIC Powder","Gesch\u00e4tzte Lesezeit":"5\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/#article","isPartOf":{"@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/"},"author":{"name":"EPIC Powder","@id":"https:\/\/www.epicmicron.com\/#\/schema\/person\/786ce0f3af110c7e79ad2d6a8fccaf39"},"headline":"Analysis of the Heavy Calcium Powder and Changes in D100","datePublished":"2024-12-13T09:19:54+00:00","dateModified":"2024-12-17T07:11:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/"},"wordCount":1013,"publisher":{"@id":"https:\/\/www.epicmicron.com\/#organization"},"image":{"@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/#primaryimage"},"thumbnailUrl":"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes.webp","articleSection":["Industry News"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/","url":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/","name":"Analyse des schweren Calciumpulvers und \u00c4nderungen in D100 - Hersteller von Strahlm\u00fchlenausr\u00fcstung","isPartOf":{"@id":"https:\/\/www.epicmicron.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/#primaryimage"},"image":{"@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/#primaryimage"},"thumbnailUrl":"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes.webp","datePublished":"2024-12-13T09:19:54+00:00","dateModified":"2024-12-17T07:11:10+00:00","description":"Es zeigte sich, dass sich die Feinpartikelgr\u00f6\u00dfe ver\u00e4nderte und der D100-Wert anstieg. Nach einer zweiten Klassifizierung stieg der D100-Wert erneut an.","breadcrumb":{"@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/#primaryimage","url":"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes.webp","contentUrl":"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2024\/12\/Calcium-carbonate-powder-of-different-particle-sizes.webp","width":900,"height":392,"caption":"Calcium carbonate powder of different particle sizes"},{"@type":"BreadcrumbList","@id":"https:\/\/www.epicmicron.com\/de\/analysis-of-the-heavy-calcium-powder-and-changes-in-d100\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.epicmicron.com\/"},{"@type":"ListItem","position":2,"name":"Analysis of the Heavy Calcium Powder and Changes in D100"}]},{"@type":"WebSite","@id":"https:\/\/www.epicmicron.com\/#website","url":"https:\/\/www.epicmicron.com\/","name":"Hersteller von Strahlm\u00fchlenausr\u00fcstung","description":"Ausr\u00fcstung zum Trocken-Ultrafeinmahlen","publisher":{"@id":"https:\/\/www.epicmicron.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.epicmicron.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.epicmicron.com\/#organization","name":"Hersteller von Strahlm\u00fchlenausr\u00fcstung","url":"https:\/\/www.epicmicron.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.epicmicron.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2021\/04\/logo.png","contentUrl":"https:\/\/www.epicmicron.com\/wp-content\/uploads\/2021\/04\/logo.png","width":350,"height":100,"caption":"Jet Mill Equipment Manufacturer"},"image":{"@id":"https:\/\/www.epicmicron.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.epicmicron.com\/#\/schema\/person\/786ce0f3af110c7e79ad2d6a8fccaf39","name":"EPIC-Pulver","url":"https:\/\/www.epicmicron.com\/de\/author\/epic-powder\/"}]}},"_links":{"self":[{"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/posts\/14860","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/comments?post=14860"}],"version-history":[{"count":0,"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/posts\/14860\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/media\/14861"}],"wp:attachment":[{"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/media?parent=14860"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/categories?post=14860"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.epicmicron.com\/de\/wp-json\/wp\/v2\/tags?post=14860"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}